CMA Dishmachines CMA-180 VL Owner's Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
MODEL CMA-180VL INSTALLATION & OPERATION Rev. 2.00 Page
16
4. Quick service guide
MODEL: CMA 180 VL HIGH TEMP
TECHNICAL ISSUE
CAUSE
SOLUTION
Door magnetic reed switch problem
Faulty magnetic reed switch
Check wire connections inside control box
Contact factory for new retrofit, corner straight
Door mechanical switch problem
Switch alignment issue
Align switch
Switch button broke
Replace switch,
Delimer switch is in
OFF
position
Flip to
NORMAL
position
Loose wire connections
Check and crimp connectors
Pump motor not running
Faulty # 3 micro switch in cam timer
Replace micro switch,
Faulty contactor
Replace contactor,
Faulty wash pump motor
Replace wash pump motor,
Faulty # 3 micro switch in cam timer
Replace micro switch,
Pump motor runs continuous
Delimer switch is in
DELIME
position
Flip to
NORMAL
position
Faulty contactor
Replace contactor,
Booster heater thermostat not properly set
Adjust thermostat
Incoming main water temperature below 140 F
Raise water temperature to 140 F
Final rinse water below 180 degree F
Tripped or faulty high limit switch
Reset or replace high limit switch,
Faulty contactor
Replace contactor,
Faulty booster heater element
Replace heating element,
Scaled heating element
De- scale heating element
Thermostat is not properly adjusted
Adjust thermostat
Loose lead connection
Check connectors and secure
Wash tank heater is not operational
Tripped or faulty high limit switch
Reset or replace high limit switch,
Faulty float switch
Replace float switch,
Faulty contactor
Replace contactor,
Faulty heating element
Replace heating element,
Water regulator not a
djusted properly
Adjust regulator to 18
-20 PSI
Clogged final rinse spray jets
Clean jets
Low water pressure at the final rinse
Missing final rinse spray end cap
Replace end cap,
Low incoming water pressure from building
Increase pressure
Water solenoid leaks
Scaled or dirty solenoid valve
Clean valve
Faulty solenoid valve diaphragm
Replace diaphragm,
Thermostat not properly set
Adjust thermostat
Wash water temperature too low/high
Scaled heating element
Clean
scale, delime machine
Faulty temperature gauge
Replace gauge,
Position or proper operation of door switch
Adjust or replace door switch,
Delimer switch is on
OFF
position
Flip to
NORMAL
position
Faulty 1st micro switch in cam timer
Replace micro switch,
Machine does not operate when the
door is closed
Check cam timer motor
Replace timer if needed,
Check ice cube relay
Replace if faulty,
Faulty wash pump contactor
Replace contactor,
Page view 14